Class 2 (Major Hazardous)TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT(CONSTRUCTION FENCE)NOTED:AT TIME OF INSPECTION ON AN ACTIVE JOB SITE,I OBSERVED THAT THE CONSTRUCTION FENCE ERECTED AROUND THE SITE ISSUED TO THE PERMIT H
Respondent: BARR & BARR INC
Issued 2020-02-07
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 1 (Immediately Hazardous)AC28-11.1=MODEL APARTMENT WITHOUT PROPER JG TO ONOTED AT TIME OF INSPECTION I OBSERVED THREE ROOMS LOCATED ON THE SIXTH FLOOR SET UP WITH FRUNITURE INSIDE EACH ROOMS THE STANDPIPE IS NOT ACTIVE IN THIS BUILDING
Respondent: HUNTER ROBERTS CONST GRP
Issued 2019-11-20
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 1 (Immediately Hazardous)3303.9 MAINTAIN MEANS OF EGRESS. NOTES:AT TIME OF MY INSPECTION I OBSERVED AN EXIT IN THE FENCE THAT WAS CHAINED AND LOCKED FROM THE OUTSIDE OF THE SITE WHICH WOULD STOP WORKERS FROM EXITING THE SITE IN CASE OF
Respondent: HUNTER ROBERTS CONST.GRP
Issued 2019-11-20
Cornell Tech (The House) (BIN #1090298)
Resolved Construction
Class 2 (Major Hazardous)WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR AMENDMENTS OBSERVED SECTION OF CHAIN LINK FENCE HAS BEEN REMOVED CREATING ACCESS TO ADJOINING PROPERTY CONTRARY TO SSP-200 ALSO THE SITE SAFETY PL
Respondent: BARR & BARR INC
Issued 2019-10-11
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Unknown
Class 1 (Immediately Hazardous)FAILED TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT RESULTED IN A FATLITY OR INJURY A WORKER SUFFERED AN INJURY TO HIS ANKLE AND WAS TAKEN TO A HOSIPTAL WHILE MOVING AN A FRAM EIWTH SHEETROCK THAT RIPPE DOVER H
Respondent: HUNTER ROBERTS CONST GRP
$1,250 Penalty
Summons #35445333H Issued 2019-07-25
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 1 (Immediately Hazardous)FAILURE TO INSTITUTE AND MAINTAIN SAFE OPERATION. NOTE: AT TIME OF MY INSPECTION RESPONDING TO COMPLAINT #1517035 WHERE IT WAS REPORTED THAT A WORKER GOT INJURIED WHILE UNLOADING SHEETROCK FORM AN "A" FRAME
Respondent: HUNTER ROBERTS CONST GRP
Issued 2019-07-25
Cornell Tech (The House) (BIN #1090298)
Resolved Construction
Class 1 (Immediately Hazardous)UNSAFE STORAGE OF MATERIAL DURING CONSTRUCTION OR DEMOLITION.AT THE TIME OF MY INSPECTION OF A PROPOSED 4 STORY NEW BUILDING I OBSERVED MATERIAL BEING STORED ON THE EDGE OF VARIOUS FLOORS IN THE MEZZANINE LEVEL
Respondent: BAB R BAR INC
$2,530 Penalty
Summons #35405482P Issued 2019-04-18
Cornell Tech (The House) (BIN #1090298)
Resolved Construction
Class 1 (Immediately Hazardous)3308.5.6 TEMPORAY REMOVAL:VERTICAL SAFETY NETTING.@TIME OF INSP OF A PROPOSED 4 STORY NEW BLDG I OBSERVED VERTICAL NETTING OPEN ON THE 4TH FL THERE WERE INDIVIDUAL ON THE FL CORE DRILING & OTHER WORKERS LEFT AR
Respondent: BAR & BAR INC
$2,530 Penalty
Summons #35405481N Issued 2019-04-18
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 2 (Major Hazardous)FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES AND TEMPORARY CONSTRUCTION. NOTE:AT THE TIME OF MY INSPECTION OF A 19 STORY BUILDING AT 19TH FL LEVEL CONSTRUCTION WORK IN PROGRESS. I OBSERVED REMOVA
Respondent: HUNTER ROBERTS CONST GRP
$5,000 Penalty
Summons #35363664N Issued 2019-03-15
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 1 (Immediately Hazardous)WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS. NOTE:AT THE TIME OF MY INSPECTION OF A 19 STORY BUILDING AT 19TH FL LEVEL CONSTRUCTION WORK IN PROGRESS. I OBSERVED THAT THER
Respondent: HUNTER ROBERTS CONST GRP
$2,500 Penalty
Summons #35363663L Issued 2019-03-15
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 1 (Immediately Hazardous)PERMIT WORK W/O A PERMIT. NOTE:AT THE TIME OF MY INSPECTION OF A 19 STORY BUILDING AT 19TH FL LEVEL CONSTRUCTION WORK IN PROGRESS. I OBSERVED A DOKA CLIMBING FORMWORK SYSTEM IN PLACE AND BEING USE FOR SHEAR WAL
Respondent: HUNTER ROBERTS CONST GRP
$1,250 Penalty
Summons #35363661H Issued 2019-03-15
Cornell Tech (Graduate Hotel) (BIN #1090301)
Resolved Construction
Class 1 (Immediately Hazardous)BC 3301.6 DESIGN,SIZES AND CAPACITY OF MATERIALS,STRUCTURES,TEMPORARY CONSTRUCTION AND EQUIPMENT. NOTE:AT THE TIME OF MY INSPECTION OF A 19 STORY BUILDING AT 19TH FL LEVEL CONSTRUCTION WORK IN PROGRESS. I OBSER
Respondent: HUNTER ROBERTS CONST GRP
Issued 2019-03-15